Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
These kits provide a simple, cost-effective solution for generating miRNA and small RNA sequencing libraries directly from total RNA, for any species.
Assay time
Hands-on time
Reagent and Library Prep Kit Bundles Available for the MiniSeq System
Order your MiniSeq reagents and library prep kits together for additional savings and convenience. Select any of item numbers 20005613 through 20005616, and add to your cart.
TruSeq Small RNA Library Preparation Kits provide reagents to generate small RNA libraries directly from total RNA. MicroRNAs (miRNAs) generated by Dicer processing are efficiently targeted by the included modified adapters.
These kits enable multiplexed sequencing with the introduction of 48 unique indexes, allowing miRNA and small RNA discovery and profiling throughput to match the unparalleled output of Illumina sequencing. Indexes are added in a universal amplification reaction, greatly reducing ligation bias and ensuring accurate measurement of miRNA expression.
Workflow improvements enable streamlined sample preparation, allowing economical studies covering all small RNA transcripts in any species. Compatible applications include finding novel miRNAs, characterizing variation such as isomers with single-base resolution, and analyzing differential expression without prior assumptions.
The Human Brain Reference RNA (HBRR) and Universal Human Reference RNA (UHRR) samples were prepared using the TruSeq Small RNA Library Prep Kit. These libraries were sequenced on the MiniSeq System using the MiniSeq High Output Reagent Kit at a 1 x 36 bp read length configuration. The total yield was 0.91 Gb with 97% of bases at or above Q30.
Browse the data In BaseSpace Sequence Hub:
View run (primary analysis and metrics)
View project (secondary analysis with BaseSpace Apps)
Assay time | 1 day |
---|---|
Hands-on time | 4 hr |
Mechanism of action | Captures small RNA with 3′ OH and 5′P modifications (like those processed by Dicer/Drosha) |
Method | mRNA Sequencing |
Multiplexing | 48 unique indexes are available |
Species category | Drosophila, Any species, Mouse, Zebrafish, Human, Rat, Plant, Nematode |
Variant class | Novel transcripts, Transcript variants |
Detect cancer gene expression and transcriptome changes and identify novel cancer transcripts with RNA next-generation sequencing (RNA-Seq).
Complex and genetic disease research
Comprehensive array and next-generation sequencing solutions to accelerate research of various genetic complex diseases.
Literature is not currently available for this product.
Library prep and array kit selector
Find the right sequencing library preparation kit or microarray for your needs. Filter by method, species, and more. Compare, share, and order kits.
TruSeq Small RNA Library Prep Kit -Set A (24 rxns) (Set A: indexes 1-12)
RS-200-0012
Includes reagents for library preparation of 24 small RNA samples for multiplexed sequencing. Each kit contains indexes 1–12 of 48 unique indexes.
List Price:
Discounts:
TruSeq Small RNA Library Prep Kit -Set B (24 rxns) (Set B: indexes 13-24)
RS-200-0024
Includes reagents for library preparation of 24 small RNA samples for multiplexed sequencing. Each kit contains indexes 13–24 of 48 unique indexes.
List Price:
Discounts:
TruSeq Small RNA Library Prep Kit -Set C (24 rxns) (Set C: indexes 25-36)
RS-200-0036
Includes reagents for library preparation of 24 small RNA samples for multiplexed sequencing. Each kit contains indexes 25–36 of 48 unique indexes.
List Price:
Discounts:
TruSeq Small RNA Library Prep Kit -Set D (24 rxns) (Set D: indices 37-48)
RS-200-0048
Includes reagents for library preparation of 24 small RNA samples for multiplexed sequencing. Each kit contains indexes 37–48 of 48 unique indexes.
List Price:
Discounts:
TruSeq Small RNA Set A MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
20005613
Kitted reagents for library preparation of 24 small RNA samples for multiplexed sequencing on the MiniSeq System. Each kit contains indexes 1-12 of 48 unique indexes. Bundle includes 2 High-Output 75 cycle MiniSeq Reagent Kits.
TruSeq Small RNA Set B MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
20005614
Kitted reagents for library preparation of 24 small RNA samples for multiplexed sequencing on the MiniSeq System. Each kit contains indexes 13-24 of 48 unique indexes. Bundle includes 2 High-Output 75 cycle MiniSeq Reagent Kits.
TruSeq Small RNA Set C MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
20005615
Kitted reagents for library preparation of 24 small RNA samples for multiplexed sequencing on the MiniSeq System. Each kit contains indexes 25-36 of 48 unique indexes. Bundle includes 2 High-Output 75 cycle MiniSeq Reagent Kits.
TruSeq Small RNA Set D MiniSeq Kit (1 library prep and 2 MiniSeq reagents)
20005616
Kitted reagents for library preparation of 24 small RNA samples for multiplexed sequencing on the MiniSeq System. Each kit contains indexes 37-48 of 48 unique indexes. Bundle includes 2 High-Output 75 cycle MiniSeq Reagent Kits.
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.