*Offer valid for library prep kit only. Index adapters and panels are not included in this promotion.
Illumina Stranded Total RNA Library Prep Training
20044764
Illumina Total RNA Prep with Ribo-Zero Plus provides exceptional performance for the analysis of coding and multiple forms of noncoding RNA. Gain high-confidence discovery of alternative transcripts, gene fusions, and allele-specific expression.
Illumina Total RNA Prep with Ribo-Zero Plus is based on TruSeq ligation technology, which has been cited in over 9,926 publications since 2011. This ligation method results in high coverage uniformity, precise strand information, and robust and reliable library preparation even from degraded samples.
Learn more about the technology
Illumina Total RNA Prep with Ribo-Zero Plus supports a broad range of RNA inputs, from 1 ng to 1000 ng*. It’s compatible with variable sample types, including formalin-fixed paraffin-embedded (FFPE) and other low-quality samples. The included Ribo-Zero Plus removes abundant RNA from multiple species, including human, mouse, rat, bacteria, and epidemiology samples.
Prepare libraries in as little as 7 hours. Illumina-qualified automation methods will be available soon through our automation partners.
Multiplex up to 384 samples and sequence in a single run. (Index Sets A and B are available now; Sets C and D are coming soon.) The number of samples sequenced per run depends on the throughput capacity of the sequencer.
*This input range is applicable to high-quality RNA. We recommend 10 ng input for best results and for FFPE or degraded samples.
仪器 | 推荐的样本数 | 读长 |
---|---|---|
NextSeq 550 System | Mid output: 2 High output: 8 (based on 50M reads per sample) |
2 × 75 bp |
NextSeq 2000 System | Whole Transcriptome Analysis: 8 (P2)-20 (P3) samples per run (based on 50M reads per sample) |
2 × 75 bp |
NovaSeq 6000 System | Whole Transcriptome Analysis: SP: 16 S1: 32 S2: 82 S4: 200 samples per run (based on 50M reads per sample) |
2 × 75 bp |
Illumina Stranded Total RNA Prep with Ribo-Zero Plus | TruSeq Stranded Total RNA | TruSeq Stranded Total RNA with Ribo-Zero Globin | |
---|---|---|---|
Assay Time | ~7 hours | ||
Automation Capability | 液体处理机器人 | 液体处理机器人 | 液体处理机器人 |
Content Specifications | Captures coding RNA plus multiple forms of non-coding RNA | Captures coding RNA plus multiple forms of non-coding RNA | |
Description | For whole-transcriptome sequencing studies of multiple sample types. Includes Ribo-Zero plus module for single-tube depletion of abundant transcripts from multiple species | For whole-transcriptome sequencing studies of blood-derived RNA. Depletes cytoplasmic and mitochondrial rRNA plus globin mRNA. | |
Hands-On Time | <3小时 | ||
Input Quantity | 1-1000 ng total RNA for standard-quality RNA samples. 10ng total RNA minimum recommended for optimal performance and FFPE samples | 0.1 – 1 ug high-quality purified total RNA from blood | |
Mechanism of Action | Enzymatic rRNA depletion, ligation-based addition of adapters and indexes | Bead-based rRNA depletion, cDNA synthesis, and PCR | |
Method | Whole-Transcriptome Sequencing | Whole-Transcriptome Sequencing | Whole-Transcriptome Sequencing |
Multiplexing | 多达384个唯一双标签序列(UDI) | High-throughput kits: Prepare 96 indexed samples using either combinatorial dual indexes or unique dual indexes, Low-throughput kits: Pool up to 12 samples. Or pool up to 24 samples with sets A and B together | |
Species Category | Bacteria, Mouse, Rat, Virus, 人类 | Mouse, Rat, 人类 | Mouse, Rat, 人类 |
Technology | 测序 | 测序 | 测序 |
Data Sheet | PDF | 6 versions
Best practices for read trimming for Illumina Stranded mRNA and Total RNA workflows
Technical Note | PDF< 1 MB
Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus Reference Guide Documentation
Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus Consumables & Equipment Documentation
Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus Documentation
Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus Checklist Documentation
自定义协议选择器
Generates customized, end-to-end instructions
全部 Illumina Stranded Total RNA Prep Ligation with Ribo-Zero Plus Support