Infinium XT

Infinium XT is a comprehensive microarray solution that enables production-scale genotyping of up to 50,000 single or multi-species custom variants. Read More...
Select Product(s)
What size kit do I need?

Infinium® XT iSelect-96 Kit (1152 samples)

20006613

Infinium XT iSelect-96 Kit (4608 samples)

20006614

Infinium XT iSelect-96 Kit (23040 samples)

20006615

Automation

AutoLoader 2.x, Single-Scanner Configuration (110/220 V)

SY-202-1001

AutoLoader 2.x, Dual-Scanner Configuration (110/220 V)

SY-202-1002

Infinium Automation Kit- 8 Tip Tecan LIMS Ready (110V)

SC-30-403

Infinium Automation Kit- 8 Tip Tecan LIMS Ready (220V)

SC-30-404

Infinium Automation Kit- 8 Tip Tecan Non-LIMS (110V)

SC-30-401

Price
 
 

Infinium Automation Kit- 8 Tip Tecan Non-LIMS (220V)

SC-30-402

Price
 
 

Instrument

iScan System (110/220V)

SY-101-1001

Accessory Products
Which accessories do I need?

Infinium® XT Assay PB20 Kit

20007420

Price
 
 

Infinium® XT Upgrade Kit (24 Beadchips)

20011101

Price
 
 

Infinium XT ST Upgrade Kit (Up to 12 BeadChip Batches)

20015526

Price
 
 

Infinium® 96-XT Tip Guide Set

20011102

Price
 
 

XT Dual Hyb Insert and Baseplate

20011759

Price
 
 

XT Flow-Through Chamber Assembly Tray

20011760

Price
 
 

Infinium® XT HT Workflow Training Kit, Reagents Only

20012126

Price
 
 

XT Hyb Chamber Gasket

20012127

Price
 
 

XT Flow Through Chamber (8 pack)

20012129

Price
 
 

Infinium XT Starter Kit (24 Beadchip) 220V

20031992

Price
 
 

Product Highlights

Comprehensive Production-Scale Screening Solution

This solution enables large-scale genetic improvement programs in agrigenomics and supports high-throughput screening for biobanks and personalized medicine initiatives. It uses a highly efficient, flexible workflow.

  • Production-Scale Genotyping: Optimized assay and 96-sample BeadChip enables processing of 100,000 to upwards of 1,000,000 samples/year per lab
  • Flexible Content: Targeted single or multispecies assays of 100s to 50,000 SNPs with at least 95% conversion rate guaranteed for custom panels
  • High Efficiency Workflow: Total assay turnaround time reduced from 3 days to 2 days with less hands-on time

Infinium XT simplifies the custom assay design process, reduces overall hands-on time, and enhances automation robot performance and utilization. The workflow offers an option to reduce the overall turnaround time, if the time to answer is more important than maximum weekly output.

Streamlined Sample Preparation and Data Analysis

A high-throughput solution like Infinium XT needs integrated systems that streamline sample preparation and analysis. The Illumina Automation Control software for the Infinium Automated Pipetting System has been updated to increase sample processing efficiency. An enhanced data analysis software solution offers real-time data generation and on-demand QC report functionality so production issues can be identified and corrected earlier in the process.

Updated GenomeStudio Software speeds up genotype cluster generation, reducing overall analysis turnaround time. Also, a genotyping module for agricultural and other applications involving polyploid species is now included.

Production-level analysis can be transitioned to Beeline Software after a cluster file is created. This software significantly reduces the time needed to observe quality performance specifications, generate genotyping reports, and analyze polyploid data, without removing the flexibility for manual intervention.

Frequently Purchased Together

Specifications

Infinium XT Workflow Example

 

Supporting Data and Figures

Infinium XT Workflow Improvements
Supporting Data and Figures

Each step of the Infinium workflow is optimized in the Infinium XT workflow, reducing the turnaround time from 3 days to 2 days.

 
Find the Right Microarray

Use our interactive tool to find the right Illumina microarray for your project type and method of interest.

Access Tool
Find the Right Microarray

There is a 100,000 sample minimum order commitment.

Related Products