Order your MiniSeq reagents and library prep kits together for additional savings and convenience. Select item 20005610 and add to your cart.

TruSight Tumor 15

这款靶向测序panel可在单次检测中以简便快速的工作流程评估实体瘤中的15个常见突变基因。Read More...
选择产品

TruSight Tumor 15 MiSeq Kit

OP-101-1001

TruSight Tumor 15 (Library Prep Only)

OP-101-1002

TruSight Tumor 15 MiniSeq Kit

20005610

产品特色

TruSight Tumor 15 uses next-generation sequencing (NGS) technology to provide a comprehensive assessment of 15 genes that are commonly mutated in solid tumors. It accurately detects low-frequency variants from 20 ng of starting DNA and is optimized for formalin-fixed, paraffin-embedded (FFPE) tumor tissue.

View the Gene List

Featuring a rapid workflow that can be easily integrated into lab procedures, this panel offers a single assay for accurate, economical, and rapid analysis of solid tumors.

This TruSight Tumor panel offers:

  • Comprehensive workflow: Assess 15 genes with one simple workflow instead of single, iterative gene testing with polymerase chain reaction (PCR)
  • Efficient: Rapid turnaround with only 3.5 hours of hands-on time, going from DNA to data in approximately 36 hours
  • Relevant gene content for solid tumors: Somatic variants selected from relevant industry guidelines1,2, key opinion leaders3,4, and pharmaceutical research
  • Sensitive variant detection from low DNA input: Accurate somatic variant detection of 5% allele frequency using 20 ng DNA from FFPE tissue samples
TruSight Tumor 15 Sample Datasets

3 human reference samples and 5 FFPE-exacted DNA samples from lung, colon, melanoma, and breast tumors were prepared using TruSight Tumor 15. These libraries were sequenced on the MiniSeq System using a high output kit at a 2 x 150 bp read length configuration with dual indexing. The total yield was 7.6 Gb with 94.9% of bases at or above Q30.

Browse the data in BaseSpace Sequence Hub:

Access to this data requires a BaseSpace Sequence Hub login.
Register for BaseSpace Sequence Hub

See All Cancer Research Panels

Frequently Purchased Together

规格

计划推荐

仪器 推荐的样本数 读长
MiniSeq System Samples per run: mid output: 2-3, high output: 8 (based on 93.5% of the bases covered at 500x minimum) 2 × 150 bp (max recommended)
MiSeq System 8 samples per run with v3 reagents (based on 93.5% of the bases covered at 500x minimum) 2 × 151 bp (max recommended)

Method-Specific Workflow Example

 
TruSight Tumor 15 Gene List
AKT1 GNA11 NRAS
BRAF GNAQ PDGFRA
EGFR KIT PIK3CA
ERBB2 KRAS RET
FOXL2 MET TP53

Kit requires MiSeq Software v2.6 or higher and the Illumina Annotation Engine. Download files

Related Products

AmpliSeq for Illumina Focus Panel

用于研究52个与实体瘤相关的基因的靶向DNA和RNA研究panel。


AmpliSeq for Illumina Custom DNA Panel

专为特异性靶点或感兴趣的基因组内容测序进行优化的靶向定制研究panel。


TruSight RNA Pan-Cancer

靶向1385个癌症基因进行基因表达、变异和融合检测研究,可用于多种RNA样本类型,包括血液、骨髓和福尔马林固定石蜡包埋(FFPE)组织。


References
  1. NCCN Clinical Practice Guidelines in Oncology Accessed 15 June 2015.
  2. Van Cutsem E, Cervantes A, Nordlinger B, Arnold D; ESMO Guidelines Working Group. Metastatic colorectal cancer: ESMO Clinical Practice Guidelines for diagnosis, treatment and follow-up. Ann Oncol. 2014;25 Suppl 3:iii1-9.
  3. Rousseau B, Jacquot C, Le Palabe J, et al. TP53 transcription factor for the NEDD9/HEF1/Cas-L gene: potential targets in non-small cell lung cancer treatment. Sci Rep. 2015;5:10356.
  4. Haley L, Tseng LH, Zheng G, et al. Performance characteristics of next-generation sequencing in clinical mutation detection of colorectal cancers [published online July 31 2015]. Mod Pathol. 2015. doi: 10.1038/modpathol.2015.86.