Targeted sequencing to detect exonic variants

Analyze the protein-coding regions of the genome to uncover genetic influences on disease and population health

Exome Sequencing

Whole-exome sequencing is a widely used next-generation sequencing (NGS) method that involves sequencing the protein-coding regions of the genome. The human exome represents less than 2% of the genome, but contains ~85% of known disease-related variants,1 making this method a cost-effective alternative to whole-genome sequencing.

Exome sequencing using exome enrichment can efficiently identify coding variants across a broad range of applications, including population genetics, genetic disease, and cancer studies.

Whole-Exome Sequencing in 3 Simple Steps

Investigate the protein-coding regions of the genome with this comprehensive workflow solution.

View Recommended Workflow  

  • Identifies variants across a wide range of applications
  • Achieves comprehensive coverage of coding regions
  • Provides a cost-effective alternative to whole-genome sequencing (4–5 Gb of sequencing per exome compared to ~90 Gb per whole human genome)
  • Produces a smaller, more manageable data set for faster, easier data analysis compared to whole-genome approaches
Whole-Exome vs. Whole-Genome Sequencing

Explore the benefits of both approaches to understand which method is best for your research.

View Infographic

Exome sequencing is a cost-effective approach when whole-genome sequencing is not practical or necessary. Sequencing only the coding regions of the genome enables researchers to focus their resources on the genes most likely to affect phenotype, and offers an accessible combination of turnaround time and price.

Exome sequencing detects variants in coding exons, with the capability to expand targeted content to include untranslated regions (UTRs) and microRNA for a more comprehensive view of gene regulation. DNA libraries can be prepared in as little as 1 day and require only 4–5 Gb of sequencing per exome.

Scientist Looking up at HiSeq

Featured Exome Sequencing Articles

DNA helix
Sequencing Thousands of Samples to Gain Insights into Novel Variants

Regeneron Genetics Center researchers perform exome sequencing analysis on patient-consented data sets to identify relevant genetic associations.

Read Article
NGS Identifies Rare Disease Variants in Infants
National Exome Sequencing Program

A landmark NGS study identifying rare disease variants in infants led to a national clinical exome sequencing program in Singapore.

Read Article
Breast Cancer
NGS Proves Invaluable for Biomarker Discovery

Researchers use exome sequencing, RNA sequencing, and other NGS methods in their search for cancer-associated gene expression profiles.

Read Article

The DRAGEN Bio-IT Platform provides accurate, ultra-rapid analysis of exome sequencing data and other NGS data across a broad range of applications.

Learn More
DRAGEN Bio-IT Platform for Whole Genome Sequencing Data Analysis

Illumina sequencing by synthesis (SBS) chemistry is the most widely adopted next-generation sequencing (NGS) technology, generating approximately 90% of global sequencing data.*

Illumina offers whole-exome sequencing workflows that simplify the entire process, from exome enrichment and library preparation to sequencing, data analysis, and biological interpretation.

Click on the below to view products for each workflow step.

Illumina DNA Prep with Exome Enrichment

A fast, integrated whole-exome enrichment and sequencing library preparation workflow for a wide range of applications.

TruSeq DNA Exome

Cost-effective library preparation and exome enrichment solution that delivers exceptional target coverage over a broad range of read depths.

Nextera DNA Exome

Fast library preparation and exome enrichment that accommodates low input amounts.

TruSight One Sequencing Panels

Comprehensive panels targeting disease-associated regions of the exome with high analytical sensitivity and specificity.

Library Prep Kit Selector Library Prep Kit Selector

Determine the best kit for your needs based on project type, starting material, and method or application.

MiSeq System

Focused power to sequence targeted regions or 1 human exome per run.

NextSeq 1000 & 2000 Systems

Groundbreaking benchtop sequencers allow you to explore new discoveries across a variety of current and emerging applications, with higher efficiency and fewer restraints.

NovaSeq 6000 System

Scalable throughput and flexibility for virtually any genome, sequencing method, and scale of project.

Platform Comparison Tool

Compare sequencing platforms and identify the best system for your lab and applications.

Sequencing Reagents

Find kits that include sequencing reagents, flow cells, and/or buffers tailored to each Illumina sequencing system.

BaseSpace Enrichment App

Performs targeted resequencing using fast and accurate Isaac algorithms for alignment and variant calling.

BaseSpace Variant Interpreter

Leverages leading annotation databases and a powerful filtering interface for rapid identification of disease-associated variants.

BaseSpace Integrative Genomics Viewer App

Associates single gene or list of genes with annotation data for pathways, diseases, tissues, and small molecules.

BaseSpace Sequence Hub

The Illumina genomics computing environment for NGS data analysis and management.

BaseSpace Correlation Engine

A growing library of curated genomic data to support researchers in identifying disease mechanisms, drug targets, and biomarkers.

Illumina DRAGEN Bio-IT Platform

The Illumina DRAGEN (Dynamic Read Analysis for GENomics) Bio-IT Platform provides ultra-rapid secondary analysis of NGS data.

NextSeq 1000 & 2000 Systems
NextSeq 1000 & 2000 Systems

Groundbreaking benchtop sequencers allow you to explore new discoveries across a variety of current and emerging applications, with higher efficiency and fewer restraints.

Learn More
Illumina DNA Prep with Enrichment
Illumina DNA Prep with Enrichment

A fast, integrated workflow for a wide range of applications providing targeted resequencing for custom panels, fixed panels, and whole-exome enrichment.

Learn More
BaseSpace Sequence Hub
BaseSpace Sequence Hub

Data management and simplified bioinformatics for labs getting started and for rapidly scaling next-generation sequencing (NGS) operations.

Learn More
Using NGS to Study Rare Undiagnosed Genetic Disease

Whole-exome and transcriptome sequencing prove beneficial in uncovering mutations and pathways associated with rare disease.

Read Interview
Choosing an NGS Company
Choosing an NGS Company

Seek out a best-in-class next-generation sequencing company with user-friendly bioinformatics tools and industry-leading support and service. See the evidence.

Cancer Exome Analysis
Cancer Exome Sequencing

This method provides useful information about coding mutations associated with tumor progression. By sequencing less than 2% of the genome, it is possible to sequence to higher depth more economically. Learn more about cancer exome sequencing.

Complex Disease Genomics
Complex disease studies

Whole-exome sequencing is a common approach to finding causal variants in cases of complex disorders. Learn more about complex disease research.

RNA Exome Capture Sequencing
Scientist in lab with HiSeq X

Achieve cost-effective, accurate, and sensitive RNA exome analysis of even difficult samples without sacrificing gene fusion discovery power. Learn more about RNA exome capture sequencing.

Rare Disease Variant Analysis
Rare disease researchers pipetting

NGS-based exome analysis can help scientists uncover variants linked to rare and undiagnosed disorders. Learn more about rare disease genomics.

 
Interested in receiving newsletters, case studies, and information on genomic analysis techniques? Enter your email address.
Brain neural network
Genetic Contributions of Cognitive Control

Exome sequencing helps researchers identify variants for an array designed for ADHD, autism, and schizophrenia studies.

Read Interview
DNA Sequencing Data Analysis
DNA Sequencing Data Analysis

Explore user-friendly tools for intuitive analysis of DNA sequencing data.

Learn More
Exome Sequencing of FFPE Samples
Whole-Exome Sequencing of FFPE Samples

Researchers in Italy developed a quality control method that enables them to sequence formalin-fixed, paraffin-embedded tissues.

Read Interview
NGS to Study Genetics of Brain Development
Genetics of Neurological Disorders

Researchers use exome sequencing, arrays, and other methods to identify gene variants linked to intellectual disability.

Read Interview
Reference
  1. van Dijk EL, Auger H, Jaszczyszyn Y, Thermes C. Ten years of next-generation sequencing technology. Trends Genet. 2014;30:418-426.

*Data calculations on file. Illumina, Inc., 2015