See how researchers use mRNA-Seq with the NextSeq 550 System.
Read eBook: Gene Expression and Regulation Research with RNA-Seq
6.5 hours/< 3 hours hands-on
A simple, scalable, cost-effective, rapid single-day solution for analyzing the coding transcriptome leveraging as little as 25 ng input of standard (non-degraded) RNA.
15–18 hours/15 minutes hands-on
Bring the power of a high-throughput sequencing system to the benchtop. The 150 cycle high-output or mid-output kits provide 2 x 75 bp reads for total RNA-Seq.
Push-button tools
Performs alignment, quantification, and fusion detection.
Enables differential gene expression analysis.
See how researchers use the NextSeq 550 System for exome sequencing applications.
1 day/3 hours hands-on
Uses a simple, one-day workflow to provide a fast path to greater understanding of the human exome.
Illumina DNA Prep with Enrichment uses a fast, user-friendly workflow. On-bead tagmentation chemistry is combined with a simplified, single hybridization protocol to reduce total workflow time.
15-18 hours/15 minutes hands-on
Bring the power of a high-throughput sequencing system to the benchtop. The 150 cycle high-output or mid-output kits provide 2 x 75 bp reads for total RNA-Seq..
Push-button tools
The on-premises DRAGEN Sever and DRAGEN on BaseSpace Sequence Hub offer rapid, accurate analysis of germline and somatic exome data.
See how researchers can use the NextSeq 550 System to sequence whole genomes:
6 hours/4 hours hands-on
Generate WGS libraries and efficiently interrogate samples with limited available DNA.
A fast, integrated workflow for a wide range of applications, from human whole-genome sequencing to amplicons, plasmids, and microbial species.
26–29 hours/15 minutes hands-on
Bring the power of a high-throughput sequencing system to the desktop. The 300 cycle high-output kit provides 2 x 150 bp reads for whole-genome sequencing.
Push-button tools
Quickly extracts biological information from whole-genome sequences, using Isaac alignment and variant calling.
The DRAGEN Germline Pipeline v3 aligns and optionally variant calls FASTQ files, outputting a BAM, VCF, or both.
The DRAGEN Somatic Pipeline aligns and variant calls Tumor-only or Tumor/Normal FASTQ files, outputting BAM(s) and a VCF.
Browse sample data sets on Basespace Sequence Hub:
NextSeq 550 v.2.5 WGS Run
NextSeq 550 v2.5 WGS Project
A targeted deep sequencing assay identifies multi-drug-resistant tuberculosis strains responsible for silent outbreaks.
Read ArticleLandmark NGS study leads to a national clinical diagnostic exome sequencing platform in Singapore.
Read InterviewThe microenvironment surrounding tumors could tell us more about how cancer cells migrate and become drug resitant.
Read InterviewA computer scientist is expanding the reach of scRNA-Seq data through new open source technologies.
Read InterviewIn addition to sequencing, the NextSeq 550 enables microarray scanning for a broad range of applications in reproductive health, genetic health, and cancer research, including methylation analysis with the Infinium MethylationEPIC BeadChip.
Use sequence-specific hybridization to analyze genomic regions of interest.
Analyze both coding RNA and multiple forms of noncoding RNA with total RNA sequencing, for a comprehensive view of the transcriptome.
NextSeq 550 System RNA-Seq Solution
Detect both known and novel features of the RNA exome using sequence-specific capture of RNA coding regions.
Targeted resequencing focuses time, expenses, and analysis on sequencing only a subset of genes or genome regions of research interest.
Targeted gene sequencing panels contain defined probe sets focused on specific genes of interest. Both predesigned and custom panels are available.
Perform epigenetic studies with high-coverage density and flexibility enabled by sequencing-based DNA methylation analysis.
Ultra-deep sequencing of PCR amplicons enables cost-effective analysis of up to hundreds of target genomic regions in one assay.
De novo sequencing with next-generation sequencing (NGS) enables fast, accurate characterization of species without a reference genome.
NextSeq 550 System WGS Solution
Delivering Sequencing Results Quickly and at a Competitive Price
Genotyping by sequencing provides a low-cost genetic screening method to discover novel plant and animal SNPs and perform genotyping studies.
Combining chromatin immunoprecipitation (ChIP) assays with sequencing, ChIP-Seq is a powerful method for genome-wide surveys of gene regulation.
Isolate and sequence small RNA species, such as microRNA, to study the role of noncoding RNA in gene silencing and posttranscriptional regulation.
Ribosome profiling enables systematic monitoring of cellular translation processes and prediction of protein abundance.
Ribosome Profiling Enables Comprehensive Translation Analysis
Comprehensively sample genes in organisms present in a complex sample to evaluate bacterial diversity and detect unculturable microorganisms.
Next-generation sequencing offers base-by-base, genome-wide detection of chromosomal variation to complement array-based cytogenomic analysis.
Find out how to utilize RNA-Seq to discover and profile RNA-based drug response biomarkers. Access resources designed to help new users adopt this application.
Quantitatively interrogate methylation sites across the genome at single-nucleotide resolution.
Environmental DNA (eDNA) sequencing is a rapidly emerging method for studying biodiversity and monitoring ecosystem changes.
eDNA Sequencing Offers a Powerful Lens to View Changes in Biodiversity
Access the information you need—from BeadChips to library preparation for genome, transcriptome, or epigenome studies to sequencer selection, analysis, and support—all in one place. Select the best tools for your lab with our comprehensive guide designed specifically for research applications.
Access Guide