以前名为TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Human/Mouse/Rat(货号RS-122-2201、RS-122-2202和RS-122-2203)和TruSeq Stranded Total RNA Library Prep Kit with Ribo-Zero Gold(货号RS-122-2301、RS-122-2302和RS-122-2303)的产品现分别更名为TruSeq Stranded Total RNA Human/Mouse/Rat和TruSeq Stranded Total RNA Gold。该产品的配置已更改。在新的配置中,文库制备试剂和标签接头均可单独购买。可单独购买的组件列表可在“选择产品”部分中找到。

TruSeq Stranded Total RNA

可靠的、扩展自如的全转录组分析(RNA-Seq)解决方案适用于各种物种与样本类型,包括人类、小鼠与福尔马林固定石蜡包埋(FFPE)样本。Read More...
选择产品
What products do I need?
Library Prep

TruSeq® Stranded Total RNA Library Prep Human/Mouse/Rat(48样本)

20020596

TruSeq® Stranded Total RNA Library Prep Human/Mouse/Rat(96样本)

20020597

TruSeq Stranded Total RNA Library Prep Gold(48样本)

20020598

TruSeq® Stranded Total RNA Library Prep Gold(96样本)

20020599


Index Adapters

TruSeq RNA CD Index Plate(96标签,96样本)

20019792

TruSeq RNA Single Indexes Set A(12标签,48样本)

20020492

TruSeq RNA Single Indexes Set B(12标签,48样本)

20020493

IDT for Illumina – TruSeq RNA UD Indexes(24标签,96样本)

20020591

IDT for Illumina – TruSeq RNA UD Indexes(96标签,96样本)

20022371

配件产品

Illumina游离接头阻断试剂(12次反应)

20024144

Illumina游离接头阻断试剂(48次反应)

20024145

产品特色

TruSeq Stranded Total RNA提供了清晰的转录组视图,为总RNA测序分析提供了经济高效的一体化可扩展解决方案。

精确测量链方向的全转录组分析

TruSeq Stranded Total RNA可兼容包括低质量DNA/RNA和福尔马林固定石蜡包埋(FFPE)样本在内的多种样本,结合了TruSeq RNA技术与Ribo-Zero核糖体RNA去除方法的所有优点。该产品可分析编码和多种形式的非编码RNA,能够精确测量链方向,实现均匀覆盖,并发现高度可信的替代转录本、基因融合和等位基因特异性表达等特征。

物种兼容性

TruSeq Stranded Total RNA专为人类、小鼠和大鼠测序而设计,但也可能适用于各类真核生物物种。

查看物种兼容表

适用于各类研究设计的灵活解决方案

TruSeq Stranded Total RNA有多种版本,可满足特定研究设计需要:

  • TruSeq Stranded Total RNA Human/Mouse/Rat可除去细胞质rRNA
  • TruSeq Stranded Total RNA Gold可除去细胞质和线粒体rRNA
  • 总RNA试剂盒兼容全新的唯一双重标签试剂盒IDT for Illumina - TruSeq RNA UD Indexes,该新试剂盒可对多达96个样本进行多重分析

查看兼容该产品的自动化系统的供应商

查看Illumina核糖体RNA清除实验方案的综合性评估

Frequently Purchased Together

规格

计划推荐

仪器 推荐的样本数 读长
NextSeq 550 System RNA Profiling: 6-20 samples per run (based on 20 million reads per sample)
Transcriptome Analysis: 2-8 samples per run (based on 50 million reads per sample)
2 x 75 bp
HiSeq 2500 System RNA Profiling: 30-200 samples per run (dual flow cell; based on 20 million reads per sample)
Transcriptome Analysis: 12-80 samples per run (dual flow cell; based on 50 million reads per sample)
2 x 75 bp
NovaSeq 6000 System RNA Profiling (samples per run, dual flow cell): S1: 160, S2: 320, S4: 768. Limited by index combinations (dual). Based on 20 million reads.
Transcriptome Analysis (samples per run, dual flow cell): S1: 64, S2: 128, S4: 400. Limited by index combinations (dual). Based on 50 million reads. 
≤ 2 × 100 bp

产品比较

TruSeq Stranded Total RNA TruSeq Stranded Total RNA with Ribo-Zero Globin
Assay Time 11.5 hours
Automation Capability 液体处理机器人 液体处理机器人
Content Specifications 捕获编码RNA以及多种形式的非编码RNA。 捕获编码RNA以及多种形式的非编码RNA。
Description For whole-transcriptome sequencing studies. The Total RNA version depletes cytoplasmic rRNA while the Total RNA Gold version depletes cytoplasmic and mitochondrial rRNA. 用于血液来源RNA的全转录组测序研究。去除细胞质rRNA、线粒体rRNA和珠蛋白mRNA。
Hands-On Time 5.5 hours
Input Quantity 0.1 – 1 ug high-quality total RNA. Lower-quality samples may require further optimization. 0.1–1 ug血液来源的高质量纯化总RNA
Mechanism of Action 基于微珠的rRNA去除、cDNA合成和PCR 基于微珠的rRNA去除、cDNA合成和PCR
Method 全转录组测序 全转录组测序
Multiplexing 低通量试剂盒:混合最多12个样本。或混合24个样本(组A和B一起), 高通量试剂盒:使用组合双标签或唯一双标签序列制备96个带标签的样本。 高通量试剂盒:使用组合双标签或唯一双标签序列制备96个带标签的样本。, 低通量试剂盒:混合最多12个样本。或混合24个样本(组A和B一起)
Specialized Sample Types FFPE Tissue Blood
Species Category 人类, 大鼠, 小鼠 人类, 大鼠, 小鼠
Species Details rRNA Removal: Depletes human, mouse, and rat rRNA
Technology 测序 测序

方法特异的工作流程示例

 

客户案例

BRC-Seq Customers Benefit from Streamlined BaseSpace Integrated Workflow

BaseSpace Sequence Hub helps the Biotechnology Resource Center Sequencing Core (BRC-Seq) at the University of British Columbia deliver high-quality sequencing data and additional value to its customers.

Read More

支持数据和图像

 
Find the Right Kit

Determine the best library prep kit or array for your needs based on your starting material and method of interest.

Access Tool
Find the Right Kit

相关产品

TruSeq Stranded Total RNA with Ribo-Zero Globin

Prepare whole-transcriptome sequencing libraries from blood-derived RNA with an efficient workflow that removes ribosomal RNA and globin mRNA in a single step.


TruSeq Stranded Total RNA with Ribo-Zero Plant

利用该RNA-Seq文库制备工作流程可全面了解植物转录组。可去除植物叶片、种子和根部组织中的rRNA。


TruSeq Stranded mRNA

从mRNA制备测序文库,获得清晰的编码转录组视图以及链特异性信息。


有限标签使用许可:此产品及其使用受Max Planck Gesellschaft所拥有且独家授权给New England Biolabs, Inc.并再授权给Illumina, Inc.的一个或多个已公告和/或待批准的美国和外国专利申请的约束。向Illumina, Inc.、其关联机构或其授权经销商和分销商购买此产品,即向买方转让使用买方所购数量产品和产品组件的权利(不论买方是学术性还是盈利性实体),该权利不可转让。购买本产品不会获得上述专利或专利申请权利请求项下的产品生产许可。买方不得向第三方出售或以其他方式转让此产品及其组件,亦不得以其他方式将此产品用于下商业用途:(1)在生产中使用此产品或其组件;或(2)出于治疗或预防疾病的目的,在人或动物身上使用此产品或其组件。