Achieve exceptionally rapid targeted RNA enrichment with the new Illumina RNA Prep with Enrichment. Use code RNA25 at checkout to receive 25% off your first order, now through the end of 2020.* 

*Offer valid for library prep kit only. Index adapters and panels are not included in this promotion.

TruSeq RNA Exome

Provides a reproducible, economical solution for sequencing RNA from FFPE tissues and other low-quality samples. Accuracy from as little as 10 ng total RNA.Read More...
选择产品
What products do I need?
Library Prep

TruSeq® RNA Library Prep for Enrichment (48 Samples)

20020189


Enrichment

TruSeq® RNA Enrichment (12 enrichments)

20020490


Index Adapters

TruSeq RNA Single Indexes Set A (12 Indexes, 48 Samples)

20020492

TruSeq RNA Single Indexes Set B (12 Indexes, 48 Samples)

20020493


Panel

Illumina Exome Panel – Enrichment Oligos Only

20020183

配件产品

Illumina® Free Adapter Blocking Reagent (12 Reactions)

20024144

Illumina® Free Adapter Blocking Reagent (48 Reactions)

20024145

产品特色

TruSeq RNA Exome, previously known as the TruSeq RNA Access Library Prep Kit, converts total RNA into template molecules of known strand origin, followed by sequence-specific capture of coding RNA. This provides a low-cost solution for analyzing human RNA isolated from formalin-fixed, paraffin-embedded (FFPE) tissues and other low-quality samples.

  • Affordability and focus—Isolating human transcriptome coding regions maximizes discovery power at a fraction of the sequencing depth
  • High-quality data from difficult samples—Optimized for sequencing RNA from degraded samples, including FFPE tissues
  • Samples with limited starting material—Greatly reduced sample input requirements (as little as 10 ng total RNA from fresh or frozen samples or 20 ng total RNA from degraded samples) while maintaining high sensitivity

TruSeq RNA Exome generates RNA sequencing (RNA-Seq) libraries from degraded samples that focus on the RNA coding regions. Isolating these high-value content regions to help maximize discovery power, while requiring only a fraction of the read depth of total RNA sequencing. The results are low input requirements, high sample throughput, and cost-effective transcriptome analysis. Reagent volumes supplied are sufficient to support 1- to 4-plex enrichment reactions.

Find automation vendors with robotic systems compatible with this product

Read a comprehensive assessment of Illumina’s ribosomal RNA depletion protocol

Frequently Purchased Together

规格

计划推荐

仪器 推荐的样本数 读长
NextSeq 550 System 5 to 16 samples per run (based on 25 million reads per sample) 2 x 75 bp
HiSeq 2500 System 24-160 samples per run (dual flow cell; based on 25 million reads per sample) 2 x 75 bp
NovaSeq 6000 System Samples per run (dual flow cell): S1: 96, S2: 96, S4: 192 (currently limited by available index combinations) 2 × 100 bp

产品比较

TruSeq RNA Exome Illumina RNA Prep with Enrichment Illumina Stranded mRNA Prep
Assay Time 约两天
Automation Capability 液体处理机器人 液体处理机器人 液体处理机器人
Content Specifications 捕获编码转录组/RNA外显子组
Description 为研究人员提供清晰、全面的编码转录组视图,链信息精确且样本起始量低。
Hands-On Time 约11小时
Input Quantity 10 ng新鲜/冷冻样本来源的总RNA,或20 ng FFPE样本来源的总RNA
Mechanism of Action 以编码RNA为靶标的生物素化的捕获探针。不要求RNA带有poly-A尾巴。
Method Exome Sequencing , mRNA Sequencing mRNA Sequencing , 靶向RNA测序 , 靶向富集 mRNA Sequencing
Multiplexing 多达24个单标签、96个组合(CD)双标签
Specialized Sample Types FFPE Tissue, Low-Input Samples Blood, FFPE Tissue, Low-Input Samples Low-Input Samples, Not FFPE-Compatible
Species Category 人类 Virus, 人类 Bovine, Mammalian, Mouse, Rat, 人类
Strand Specificity Stranded Non-Stranded Stranded

The product previously known as the TruSeq RNA Access Library Prep Kit (Cat. No. RS-301-2001 and RS-301-2002) is now called TruSeq RNA Exome. The product configuration has changed. In the new configuration, major components such as library preparation, index adapters, enrichment reagents, and exome panels can be purchased separately. If you were previously buying Cat. No. RS-301-2001 or Cat. No. RS-301-2002, purchase the following components: TruSeq RNA Library Prep for Enrichment (Cat. No. 20020189), TruSeq RNA Enrichment (Cat. No. 20020490), Exome Panel (Cat. No. 20020183), and one item from the Index Adapters section below.

Method-Specific Workflow Example

 

Customer Stories

Supporting Data and Figures

Efficient Gene Fusion Discovery
Supporting Data and Figures

TruSeq RNA Exome enables detection of expressed fusion transcripts without the need to design probes specific for the fusion junction. The well-characterized BCR-ABL fusion is detected efficiently in the Universal Human Reference RNA (UHRR) sample at 25 M reads.

 

Related Products