Illumina Stranded mRNA Prep

A simple, scalable, cost-effective, rapid single-day solution for analyzing the coding transcriptome leveraging as little as 25 ng input of standard (non-degraded) RNA.Read More...
选择产品
What products do I need?
Library Prep

Illumina® Stranded mRNA Prep Ligation 16 Samples

20040532

Illumina® Stranded mRNA Prep Ligation 96 Samples

20040534


Index Adapters

IDT® for Illumina® RNA UD Indexes Set A Ligation (96 indexes, 96 samples)

20040553

IDT® for Illumina® RNA UD Indexes Set B Ligation (96 indexes, 96 samples)

20040554

Product Highlights

Illumina Stranded mRNA Prep offers a streamlined RNA-Seq solution for clear and comprehensive analysis across the transcriptome. It offers extraordinary flexibility for input type and supports low input amounts, down to 25 ng total RNA. Illumina Stranded mRNA Prep enables precise measurement of strand orientation, uniform coverage, and high-confidence discovery of features such as novel isoforms, gene fusions, and allele-specific expression.

Exceptional Performance

Illumina Stranded mRNA Prep is optimized to provide exceptional polyA capture efficiency and coverage uniformity. It minimizes the required sequencing depth for accurate, unbiased detection of the coding transcriptome. Illumina Stranded mRNA Prep is based on TruSeq ligation technology, which has been cited in over 9,926 publications since 2011.

Learn more about the technology

Flexibility for Many Study Designs

Illumina Stranded total RNA Prep supports a broad range of RNA inputs, from 25 ng to 1000 ng.*

Precise Measurement of Strand Orientation

This information enables detection of antisense transcription, enhances transcript annotation, and increases alignment efficiency.

Fast, Automation-friendly Workflow

Prepare libraries for sequencing in less than 7 hours. Illumina-qualified automation options are coming soon through our automation partners.

Sequencing Scalability

Multiplex up to 384 samples and sequence in a single run. (Index Sets A and B are available now; Sets C and D are coming soon.)

The Power of RNA-Seq

RNA-Seq is increasingly the platform of choice for thought leaders, providing a detailed snapshot of the transcriptome at a given point in time. It offers numerous advantages over quantitative PCR, including:

  • Hypothesis-free experimental design, requiring no previous knowledge of the transcriptome 
  • Higher discovery power to detect known and novel transcripts 
  • Higher throughput capability to quantify hundreds to thousands of regions in each assay 
  • Broader dynamic range, providing more accurate measurement of gene expression 
  • More data per assay, providing full sequence and variant information

*Not compatible with FFPE samples

Frequently Purchased Together

规格

计划推荐

仪器 推荐的样本数 读长
NextSeq 550 System Mid Output: 5
High Output: 16
(based on 25M reads per sample)
2 × 75 bp
NextSeq 2000 System P2: 16
P3: 40
(based on 25M reads per sample)
2 × 75 bp
NovaSeq 6000 System SP: 32
S1: 64
S2: 164
S4: 384
(based on 25M reads per sample)
2 × 75 bp

产品比较

Illumina Stranded mRNA Prep TruSeq Stranded mRNA TruSeq RNA Library Prep Kit v2 Illumina RNA Prep with Enrichment Illumina Stranded Total RNA Prep with Ribo-Zero Plus
Automation Capability Liquid Handling Robots Liquid Handling Robots Liquid Handling Robots Liquid Handling Robots Liquid Handling Robots
Technology Sequencing Sequencing Sequencing Sequencing Sequencing
Variant Class Gene Fusions, Novel Transcripts, Single Nucleotide Polymorphisms (SNPs), Transcript Variants Gene Fusions, Novel Transcripts, Single Nucleotide Polymorphisms (SNPs), Transcript Variants Gene Fusions, Novel Transcripts, Single Nucleotide Polymorphisms (SNPs), Transcript Variants Gene Fusions, Novel Transcripts, Single Nucleotide Polymorphisms (SNPs), Transcript Variants Gene Fusions, Novel Transcripts, Single Nucleotide Polymorphisms (SNPs), Transcript Variants

Method-Specific Workflow Example

 

Supporting Data and Figures

 

Related Products

Illumina RNA Prep with Enrichment

Achieve rapid, targeted interrogation of an expansive number of target genes with exceptional capture efficiency and coverage uniformity.


Illumina Stranded Total RNA Prep with Ribo-Zero Plus

Rapid library preparation from a broad range of sample types for studying the coding and non-coding transcriptome with unparalleled study flexibility.