Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
These arrays support economical large-scale human genotyping studies, with high-throughput capabilities and the option to add up to 300K semi-custom markers.
Sample throughput
Number of samples
Number of markers
The HumanCore-24 BeadChip Kit has been renamed to Infinium Core-24 Kit. Kits with either name on the label contain the same quality reagents and follow the same workflow.
The customizable Infinium Core-24 BeadChip offers an economical way to perform and support large genetics studies. Developed in collaboration with several leading research institutions, the Infinium Core-24 BeadChip contains highly informative genome-wide tag SNPs found across diverse world populations, additional high-value markers (including indels and updated exome-focused content), and has the capacity to include up to 300,000 semi-custom markers.
In addition to cost-effectively performing large-scale genotyping studies, this BeadChip can be used to quickly and easily obtain baseline sample datasets for a variety of downstream applications, including common variant, mtDNA, ancestry, sex confirmation, loss-of-variant, indel, and CNV detection studies.
The Infinium Core-24 BeadChip is based upon the trusted Infinium assay. Using the proven iScan System, this 24-sample BeadChip combines affordability with high-throughput sample processing to deliver high-quality, genome-wide information.
Description | A customizable research array that contains highly informative genome-wide tag SNPs found in diverse world populations, additional high-value markers (including indels and exome-focused content), and the capacity to add up to 300,000 semi-custom markers. |
---|---|
Input quantity | 200 ng DNA |
Number of markers |
307,342 fixed markers. Custom marker add-on capacity: Up to 300,000 (with + kit versions) |
Number of samples | 24 samples per array |
Sample throughput | ~2304 samples per week (estimate for 1 iScan System, 1 AutoLoader 2.x, 2 Infinium Automated Pipetting Systems, and a 5-day work week) |
Match your chosen kit size to the number of samples you run at a time. Each kit is processed as a single batch and is not designed to be divided across multiple experiments. If you are processing several low-throughput batches, order multiple small kits.
Genotyping by sequencing is a genetic screening method for discovering novel plant and animal SNPs and performing genotyping studies.
Large-scale genotyping with microarrays can identify variants associated with disease risk in large cohorts or populations.
Microarray Data Analysis & Experimental Design
Find microarray data analysis tools and tips to help you to visualize and analyze microarray data and facilitate data analysis for large experiments.
Infinium Core-24 Kit | Infinium OmniExpress-24 Kit | Infinium Global Screening Array-24 Kit | |
---|---|---|---|
Automation capability | Liquid Handling Robots, Automated Array Loader | Liquid Handling Robots, Automated Array Loader | |
Description | A customizable research array that contains highly informative genome-wide tag SNPs found in diverse world populations, additional high-value markers (including indels and exome-focused content), and the capacity to add up to 300,000 semi-custom markers. |
The Infinium Global Screening Array-24 Kit is an economical genotyping array for population-scale genetics, translational research, variant screening studies, and precision medicine research, combining optimized multiethnic genome-wide content, curated clinical research variants, and QC markers. |
|
Input quantity | 200 ng DNA | 200 ng DNA | |
Instruments | iScan System | iScan System | |
Nucleic acid type | DNA | DNA | |
Number of markers |
307,342 fixed markers. Custom marker add-on capacity: Up to 300,000 (with + kit versions) |
654,027 fixed markers. Custom marker add-on capacity: Up to 100K. |
|
Number of samples | 24 samples per array | 24 samples per array | |
Sample throughput | ~2304 samples per week (estimate for 1 iScan System, 1 AutoLoader 2.x, 2 Infinium Automated Pipetting Systems, and a 5-day work week) | ~5760 samples per week | |
Species category | Human | Human | |
Technology | Microarray | Microarray | |
Variant class | Single nucleotide polymorphisms (SNPs), Germline variants, Structural variants, Insertions-deletions (indels), Copy number variants (CNVs) | Single nucleotide polymorphisms (SNPs), Structural variants, Copy number variants (CNVs) |
Infinium Core-24 v1.2 Kit (48 Samples)
20024566
The Infinium Core-24 v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip. Each Kit contains 2 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 48 DNA samples.
List Price:
Discounts:
Infinium Core-24 v1.2 Kit (288 samples)
20024567
The Infinium Core-24 v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip. Each Kit contains 12 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 288 DNA samples.
List Price:
Discounts:
Infinium Core-24 v1.2 Kit (1152 samples)
20024568
The Infinium Core-24 v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip. Each Kit contains 48 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 1152 DNA samples.
List Price:
Discounts:
Infinium Core-24+ v1.2 Kit (48 Samples)
20024569
The Infinium Core-24+ v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 2 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 48 DNA samples.
Infinium Core-24+ v1.2 Kit (288 Samples)
20024660
The Infinium Core-24+ v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 12 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 288 DNA samples.
Infinium Core-24+ v1.2 Kit (1152 Samples)
20024661
The Infinium Core-24+ v1.2 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.2 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 48 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 1152 DNA samples.
Infinium Core-24+ v1.1 Kit (48 Samples)
20015257
The Infinium Core-24 v1.1 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.1 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 2 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 48 DNA samples.
Infinium Core-24+ v1.1 Kit (288 Samples)
20015258
The Infinium Core-24 v1.1 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.1 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 12 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 288 DNA samples.
Infinium Core-24+ v1.1 Kit (1152 Samples)
20015259
The Infinium Core-24 v1.1 Kit offers a highly economical way to perform large-scale genetic studies. The Infinium Core-24 v1.1 BeadChip is a 24- sample HTS format BeadChip and supports up to 300K custom-defined BeadTypes. Each Kit contains 48 BeadChips, along with reagents for amplifying, fragmenting, hybridizing, labeling and detecting 1152 DNA samples.
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.