Order the NovaSeq X Series
Advanced chemistry, optics, and informatics combine to deliver exceptional speed and data quality, outstanding throughput and scalability.
Targeted sequencing panel that assesses germline mutations across 113 genes and 125 SNPs associated with genetic cancer risk predisposition.
Assay time
Hands-on time
Input quantity
The TruSight Hereditary Cancer Panel delivers expert-defined content for assessing germline mutations.
The panel was developed with input from key opinion leaders and includes 10,341 probes across 113 genes and 125 SNPs.
The panel is used with the Illumina DNA Prep with Enrichment library prep workflow, which takes advantage of enzyme-based DNA fragmentation, removing the instrument cost and need for mechanical fragmentation. Illumina DNA Prep with Enrichment has been qualified with multiple automation systems for a user-friendly workflow.
Indexes available for up to 384 samples allow for flexible batch sizes and scalability across Illumina benchtop sequencing systems.
Assay time |
~48 hr from DNA to data |
---|---|
Automation capability | Liquid Handling Robots |
Cancer type | Pan-Cancer, Solid Tumor |
Content specifications | Targets 113 cancer risk-associated genes |
Description |
The TruSight Hereditary Cancer Panel is a targeted sequencing panel designed to assess germline mutations across 113 genes and 125 single nucleotide polymorphisms (SNPs) for identification purposes and polygenic risk scoring. |
Hands-on time | ~2 hr |
Input quantity |
50–1000 ng DNA |
Instruments | MiSeq System, iSeq 100 System, NextSeq 550 System, MiniSeq System, NextSeq 550Dx in Research Mode, NextSeq 500 System |
Method | Target Enrichment, Targeted DNA Sequencing |
Nucleic acid type | DNA |
Sample type details |
Genomic DNA |
Specialized sample types | Blood, Saliva |
Species category | Human |
Technology | Sequencing |
Variant class | Germline variants, Insertions-deletions (indels), Copy number variants (CNVs) |
The TruSight Hereditary Cancer Panel workflow requires the TruSight Hereditary Cancer enrichment oligos, Illumina DNA Prep with Enrichment, Illumina DNA/RNA UD indexes, and sequencing reagents.
TruSight Hereditary Cancer Panel is a highly efficient targeted next-generation sequencing (NGS) panel that enables researchers to access an expert-defined content set for analyzing variation within genes previously linked with a predisposition towards cancer.
TruSight Hereditary Cancer – Enrichment Oligos
Illumina DNA Prep with Enrichment
Illumina DNA/RNA UD Indexes
Instrument | Recommended number of samples | Read length |
---|---|---|
iSeq 100 System | Samples per run: 2 (based on 300× mean coverage) |
2 × 150 bp (max recommended) |
MiniSeq System | Samples per run: mid-output: 5, high-output: 16 (based on 300× mean coverage) |
2 × 150 bp (max recommended) |
MiSeq System | Samples per run: v2 Micro: 2, v2 Standard: 9, v3 Standard: 16 (based on 300× mean coverage) |
2 × 150 bp (max recommended) |
NextSeq 500 System | Samples per run: mid-output: 80, high-output: 256 (based on 300× mean coverage) |
2 × 150 bp (max recommended) |
NextSeq 550 System | Samples per run: mid-output: 80, high-output: 256 (based on 300× mean coverage) |
2 × 150 bp (max recommended) |
Includes 10,341 probes that target 113 genes related to cancer predisposition, recommended in key guidelines, and evaluated on population studies of cases vs. controls.
The TruSight Hereditary Cancer Panel includes an extensive list of genes commonly associated with hereditary predisposition to breast, colon, ovarian, and gastric cancers and recommended in key guidelines.
TruSight Hereditary Cancer – Enrichment Oligos Only (8 Enrichment Reactions)
20029551
TruSight Hereditary Cancer – Enrichment Oligos Only (8 Enrichment Reactions)
List Price:
Discounts:
Illumina® DNA Prep with Enrichment, (S) Tagmentation (96 Samples)
20025524
Includes reagents for preparing and enriching 96 libraries (eight, 12-plex enrichment reactions). Purchase enrichment probe panel, Illumina Purification Beads and index adapters separately.
List Price:
Discounts:
Illumina® DNA Prep with Enrichment, (S) Tagmentation (16 Samples)
20025523
Includes reagents for preparing and enriching 16 libraries (16, 1-plex enrichment reactions). Purchase enrichment probe panel, Illumina Purification Beads and index adapters separately.
List Price:
Discounts:
Illumina® DNA Prep, (S) Tagmentation (96 Samples)
20025520
Includes reagents for preparing 96 libraries. No enrichment reagents are included. Purchase enrichment probe panel, Illumina Purification Beads and index adapters separately. Enrichment reagents are only orderable with library prep reagents (Illumina DNA Prep with Enrichment, (S) Tagmentation (96 samples)).
List Price:
Discounts:
Illumina® DNA Prep, (S) Tagmentation (16 Samples)
20025519
Includes reagents for preparing 16 libraries. No enrichment reagents are included. Purchase enrichment probe panel, Illumina Purification Beads and index adapters separately. Enrichment reagents are only orderable with library prep reagents (Illumina DNA Prep with Enrichment, (S) Tagmentation (16 samples)).
List Price:
Discounts:
Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples)
20091654
Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples)
20091656
Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
Illumina® DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples)
20091658
Illumina® DNA/RNA UD Indexes Set C, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
Illumina® DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples)
20091660
Illumina® DNA/RNA UD Indexes Set D, Tagmentation (96 Indexes, 96 Samples) Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
IDT® for Illumina® DNA/RNA UD Indexes Set A, Tagmentation (96 Indexes, 96 Samples)
20027213
Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
IDT® for Illumina® DNA/RNA UD Indexes Set B, Tagmentation (96 Indexes, 96 Samples)
20027214
Includes 96, 10 bp indexes sufficient for labeling 96 samples. Purchase library prep and enrichment reagents and probe panels separately.
List Price:
Discounts:
iSeq 100 i1 Reagent v2 (300-cycle)
20031371
Includes one i1 flow cell and one pre-filled cartridge containing clustering and sequencing reagents to support a 300-cycle run on the iSeq 100 System.
List Price:
Discounts:
iSeq 100 i1 Reagent v2 (300-cycle) 4 pack
20031374
Includes four i1 flow cells and four pre-filled cartridges containing clustering and sequencing reagents to support 4 × 300-cycle runs on the iSeq 100 System.
List Price:
Discounts:
iSeq 100 i1 Reagent v2 (300-cycle) 8 pack
20040760
Includes eight i1 flow cells and eight pre-filled cartridges containing clustering and sequencing reagents to support 8 × 300-cycle runs on the iSeq 100 System.
List Price:
Discounts:
MiSeq Reagent Micro Kit v2 (300-cycles)
MS-103-1002
Provides kitted reagents for up to 325 cycles of sequencing on the MiSeq System using the MiSeq Micro Flow Cell (up to 4M clusters PF). Includes: Paired End Reagent plate (300-cycles), MiSeq Micro Flow Cell, and Wash Buffer.
List Price:
Discounts:
MiSeq Reagent Kit v2 (300-cycles)
MS-102-2002
MiSeq v2 Reagent kit, 300 cycles per kit.
List Price:
Discounts:
MiSeq Reagent Kit v3 (600-cycle)
MS-102-3003
Provides kitted reagents for up to 625 cycles of sequencing on the MiSeq System. Includes: Paired-End Reagent plate (600-cycles), MiSeq Flow Cell, and Wash Buffer.
List Price:
Discounts:
MiniSeq Mid Output Kit (300-cycles)
FC-420-1004
Provides kitted reagents for 300 cycles of sequencing, plus dual- indexing support on a Mid Output run (up to 8M reads). Includes: Mid Output Reagent Cartridge (300 cycles), Flow Cell, and Hybridization Buffer.
List Price:
Discounts:
MiniSeq High Output Reagent Kit (300-cycles)
FC-420-1003
Provides kitted reagents for 300 cycles of sequencing, plus dual- indexing support on a High Output run (up to 25M reads). Includes: High Output Reagent Cartridge (300 cycles), Flow Cell, and Hybridization Buffer.
List Price:
Discounts:
NextSeq 500/550 Mid Output Kit v2.5 (300 Cycles)
20024905
Provides kitted reagents for 300 cycles of sequencing, plus dual- indexing support on a Mid Output run (up to 130M reads). Includes: Mid Output Reagent Cartridge (300 cycles), Mid Output Flow Cell Cartridge, and Buffer Cartridge.
List Price:
Discounts:
NextSeq 500/550 High Output Kit v2.5 (300 Cycles)
20024908
Provides kitted reagents for 300 cycles of sequencing, plus dual- indexing support on a High Output run (up to 400M reads). Includes: High Output Reagent Cartridge (300 cycles), High Output Flow Cell Cartridge, and Buffer Cartridge.
List Price:
Discounts:
Flex Lysis Reagent Kit (96 reactions)
20018706
Includes reagents for processing blood samples with the Illumina DNA Prep and Illumina DNA Prep with Enrichment. Purchase library prep, enrichment, enrichment probe panel, and index adapter reagents separately.
List Price:
Discounts:
Showing of
Product
Qty
Unit Price
Product
Catalog ID
Quantity
Unit price
The TruSight Hereditary Cancer Panel includes an extensive list of genes commonly associated with hereditary predisposition to breast, colon, ovarian, and gastric cancers.
The TruSight Hereditary Cancer Panel can be run on any benchtop Illumina sequencing system (iSeq 100, MiSeq, MiniSeq, and NextSeq Systems).
TruSight Hereditary Cancer Panel includes 125 SNPs. Of these, 48 are ID SNPs and 77 are used for polygenic risk scoring (PRS).
Reach out for information about our products and services, or get answers to questions about our technology.
Your email address is never shared with third parties.